SG Security Communications MLR2-E Bedienungsanleitung Seite 21

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 59
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 20
Form Number.: 7-3005 File Name: SG Automation Output Revision/Date: 01/May 3, 2005
Department: Engineering
Division: Embedded Software Form Template Owner: Jeff Cougler
21
R98761[#1234|Nri7/id009ET002][DC4]
R98761[#1234|Nri7/pi010UA002][14]
Commonly used modifiers:
Signal Modifier
Level Lv
Value va
Area ri
ID id
Path pa
Phone ph
Time ti
SDI pi
RG rg
Sked ai
NOTES: If the panel requests a translation, the receiver converts point data to zonex format and user IDs to Comex format. If
there is no request for translation, points and IDs are transmitted to automation and printed with no conversion. User ID and
point data are translated as shown below.
Point Zonex
001-008 100-800
009-024 101-116
025-040 201-216
041-056 301-316
057-072 401-416
073-088 501-516
089-104 601-616
105-120 701-716
121-136 801-816
137-152 117-132
153-168 217-232
169-184 317-332
185-200 417-432
201-216 517-532
217-232 617-632
233-247 717-731
Id Comex
0 0
1-5 001-005
06-13 601-608
14-21 701-708
22-29 801-808
30-37 B01-B08
38-45 C01-C08
46-53 D01-D08
54-61 E01-E08
62-69 F01-F08
70-249 000