Form Number.: 7-3005 File Name: SG Automation Output Revision/Date: 01/May 3, 2005
Department: Engineering
Division: Embedded Software Form Template Owner: Jeff Cougler
39
O represents Call
Q represents remote programming
R represents Test Transmission
T represents Closing
U represents Opening
ZZ = the zone or user number.
[DC4] = the terminator character.
4.27 VONK (V)
Static Format:
VRRLAA123456789ABCDEFG[DC4]
where
V = Protocol number
RR = Receiver number
L = Line card number
AA = Account code
1-G = Zone 01-16
[DC4] = Hex 14 as terminator
Dynamic Format
1RRLssssss00AAsEssZZ[DC4]
4.28 SURTEC PROTOCOL (Y)
YRRLLLsAAAAAAAAsT
1
…T
n
[DC4]
Y = Surtec protocol identifier
RR = Virtual receiver number
LLL = Virtual Line number
s = spaces
AAAAAAAA = Account code.
T
1
-T
n
= Alarm Information
Each event is represented by 2 digits. Each digit in the range of 0-9. Event codes range from 01-99. Restore is represented by
the event code followed by 09. The maximum number of events in one transmission will be limited to 8 events per message.
From example below, 8 2 0 9 will be considered as one event. Thus, maximum of 32 bytes of buffer space will be allocated for
the event frame section of the received data.