Form Number.: 7-3005 File Name: SG Automation Output Revision/Date: 01/May 3, 2005
Department: Engineering
Division: Embedded Software Form Template Owner: Jeff Cougler
41
Static Format:
VRRLAA123456789ABCDEFG[DC4]
where
V = Protocol number
RR = Receiver number
L = Line card number
AA = Account code
1-G = Zone 01-16
[DC4] = Hex 14 as terminator
Dynamic Format
1RRLssssss00AAsEssZZ[DC4]
4.32 SG Westec Formats Automation Output (W)
4.32.1 Westec Data line type (01: Housekeeping messages) (Modular
Format):
WRRLLLGGGMMEIITTTTSSPPCCUAAAADDDRPPPPPPPPPPXlFUKK[DC4]
Where, W : Westec Protocol number.
Header
RR : Receiver number. (DNIS)
LLL : Line number. (DNIS)
GGG : Cage ID is receiver id. First Two bytes are shelf ID in Hex, last byte is Slot ID in Hex
MM : Programming Checksum, Always spaces.
E : Telephone line number. Always space.
Body
II : Data line type 01. This is the type of data line.
TTTT : Transaction number, spaces.
SS : Dialer Type. (received from start line)
PP : Programmed line account suffix. (Stored in DNIS).
CC : Call attempts ( may be decimal ) made by the dialer,
U : Undefined. Always spaces.
AAAA : Account Code, 4 digits
DDDR : Location Code and Rotary Code. Received from the dialer or Stored DDD if the dialer does not send it.
PPPPPPPPPP : Temporary phone number.
X : Phone line ID sent by dialer ( systems with 2 phone lines )
l : Talk in digit. 0 = no talk in, 1 =talk in
F : Foreign Account flag. 0 = home account, 1 = foreign account (Location in DNIS must Match to Location ID
to product Home = 0)
U :Unidentified - Space
KK : Checksum calculated on all preceding digits from receiver.
[DC4] : Terminator, 14 Hex.