25
New restore identified by auxiliary channel X on zone 4.
Code 4 Example
New closing (previously unreported )
12345545555554
New closing identified by auxiliary channel 4 from user ID 3.
Code 5 Example
Normal (no event since previously reported restore)
1234155555555X
New event identified by auxiliary channel X on zone 1, all other zones are OK.
Code 6 Example
Previous reported event still in effect
1234655555555X
Event previously identified by auxiliary channel X on zone 1 is still active.
Code 0 Example
New trouble
12345055555557
New Trouble on zone 2.
(0 can also be sent as A)
4.14.2 Auxiliary Channel/Zone (Last Digit)
For the ninth channel (usually digit 13), the following channel status codes are used in addition to the Zone Status Code:
Auxiliary Code 1 Example
Duress report
Panel sends:
1234555555551
Description: Duress Report
Auxiliary Code 2 Examples
Opening report in the previous 8 channels (with user ID in channel 1)
Panel sends:
1234355555552
Description: Opening Report with user ID 3
Panel sends:
1234255555552
Description: Opening Report with user ID 2
Panel sends:
1234552555552
Seitenansicht 24