Form Number.: 7-3005 File Name: SG Automation Output Revision/Date: 01/May 3, 2005
Department: Engineering
Division: Embedded Software Form Template Owner: Jeff Cougler
26
Description: Opening Report with user ID 2
Auxiliary Code 3 Example
Zone Bypass/Unbypass status report in the previous 8 channels
Panel sends:
1234551555553
Description: Zone 3 Bypass
Panel sends:
1234155555553
Description: Zone 1 Bypass
Panel sends:
1234355555553
Description: Zone 1 UnBypass
Auxiliary Code 4 Example
Closing report in the previous 8 channels ( with user ID in channel 1)
Panel sends:
1234255555554
Description: Closing Report with user ID 2
Auxiliary Code 5 Example
Zone trouble active / trouble restore status report in the previous 8 channels
Panel sends:
1234155555555
Description: Zone trouble active on zone 1
Panel sends:
1234555155555
Description: Zone trouble active on zone 4
Panel sends:
1234555355555
Description: Zone trouble restoral on zone 4
Auxiliary Code 6 Example
System trouble active/restore reports in the previous 8 channels
Zone 1 AC lost
Zone 2 Low Battery
Zone 3 System Flow
Zone 4 Watch Dog Timer
Zone 5 System Message
Zone 6 Telco
Zone 7 not used
Zone 8 Sensor
Panel sends:
1234155555556
Description: AC lost